Low Voltage Fuse Boxes, capable of indoor and outdoor installation. Designed for 1, 2, 4, 5, 8 and 12 outgoing connections.
They are manufactured by STALCO S.A. for 50 years.
Αccording to the PPC Technical Description ND – 328/08.07.2008 and the IEC 60947.
The 1,2,4 outgoing connections Fuse Boxes include three fuse rails, one for each phase.
The Fuse Boxes with 5,8,12 outgoing connections are manufactured with a fuse unit, which is composed of three single pole fuse rails, installed vertically. In addition, these Fuse Boxes include a load break switch and an isolator with the right dimensions to adjust to the Fuse Box perfectly.
At STALCO S.A., with a 50 - year experience in manufacturing Low Voltage Fuse Boxes, we have at our disposal the most experienced and well-trained staff and the best facilities for the manufacture and the quality control at all the stages of the production process.
The Low Voltage Fuse Boxes are capable of outdoor installation in direct exposure to sun, rain and snow. Their anti – corrosive protection and special coloration makes them capable to operate in the harshest environmental conditions and high pollution levels trouble - free.
Ambient Temperature |
|
-5οC to +40οC |
Altitude |
|
1.000 m |
Pollution Level |
|
Moderate to Heavy |
Outgoing Connections |
|
1 |
|
2 |
|
4 |
|
5 |
|
8 |
|
12 |
|
12 (Reduced Dimensions) |
Rated Voltage |
230/400 V |
|||||||||||||
Rated Frequency |
50 Hz |
|||||||||||||
Rated Current |
|
80 A |
|
160 A |
|
630 A |
|
800 A |
|
1.250 A |
|
1.600 A |
|
1.600 A |
Insulation Strength |
2,5 kV, 50 Hz, 1 min. |
|||||||||||||
Thermal Current Ith |
|
1,8 kA rms, 1 sec |
|
3,6 kA rms, 1 sec |
|
10 kA rms, 1 sec |
|
16 kA rms, 1 sec |
|
24 kA rms, 1 sec |
|
24 kA rms, 1 sec |
|
24 kA rms 1 sec |
Dynamic Current Idyn |
|
3 kA |
|
6,1 kA |
|
17 kA |
|
34 kA |
|
50 kA |
|
50 kA |
|
50 kA |
Outgoing Connections |
|
1 |
|
2 |
|
4 |
|
5 |
|
8 |
|
12 |
|
12 (Reduced Dimensions) |
Width |
|
330 |
|
400 |
|
800 |
|
1.170 |
|
1.557 |
|
2.150 |
|
1.847 |
Height |
|
380 |
|
957 |
|
1.000 |
|
1.500 |
|
1.500 |
|
1.500 |
|
1.500 |
Depth |
|
160 |
|
320 |
|
400 |
|
350 |
|
350 |
|
350 |
|
350 |
Net Weight(kgr) |
|
10,5 |
|
34 |
|
80 |
|
170 |
|
253 |
|
343 |
|
320 |
Ingress Protection |
IP 43 |
IP 33 D |
IP 20 |
1 Outgoing Connection |
430001589 |
2 Outgoing Connections |
430001590 |
4 Outgoing Connections |
430001656 |
5 Outgoing Connections |
430021552 |
8 Outgoing Connections |
430021564 |
12 Outgoing Connections |
430021874 |
Contract No. |
Year |
Pieces |
ΔΜΚΔ-10957/Β4 |
1973 |
3.300 |
ΔΜΚΔ-11349/12 |
1974 |
5.000 |
ΔΜΚΔ-12379/12 |
1978 |
340 |
ΔΜΚΔ-12647/12 |
1978 |
4.000 |
ΔΜΚΔ-12749/12 |
1979 |
2.400 |
760.1193 |
1990 |
200 |
5800006 |
1990 |
4.000 |
8011082 |
1990 |
300 |
5800046 |
1992 |
433 |
5800073 |
1993 |
100 |
5800100 |
1994 |
900 |
5800118 |
1995 |
1.475 |
5800130 |
1995 |
2.505 |
5800159 |
1997 |
2.195 |
5800182 |
1998 |
300 |
5800220 |
1999 |
400 |
5800253 |
1999 |
320 |
5800289 |
2001 |
587 |
5042061 |
2002 |
548 |
5042111 |
2003 |
501 |
5042321 |
2004 |
695 |
5044392 |
2005 |
573 |
5046032 |
2006 |
1.118 |
5047132 |
2007 |
715 |
5077102 |
2008 |
125 |
5078032 |
2008 |
70 |
5078022 |
2008 |
1.383 |
5058052 |
2009 |
143 |
5059022 |
2010 |
1.339 |
5051012 |
2011 |
274 |
5033102 |
2015 |
350 |
5036042 |
2017 |
672 |
5039051 |
2021 |
6.250 |
5031122 |
2022 |
4.244 |
Total |
47.755 |